AC 85-264V Insertion Ultrasonic Heat Flowmeter  

◆Before installation, verify that pipe and fluid parameters are correctly set to ensure correct installation. ◆ Select the installation method     The installation method of the plug-in sensor is the "Z" method ◆ Installation process Select the installation method → Enter the measurement parameters → Locate the installation point → Secure the ball valve base → Open the hole and install and debug the sensor → Check the installation ◆ Input measurement parameter Settings ◆ Select the installation position and installation point positioning     Plug-in sensors are suitable for pipes ≥DN50. Installation Method Select the "Z" method. When installing, the vertical distance between the two sensors along the direction of the tube axis is equal to the installation distance, and ensure that the two sensors are on the same axis plane, and pay attention to the transmission direction must…

Website:

A Picture Interactive Platform For Global Opportunities

Copyrights © 2024 chsafetypadlock.com All Rights.Reserved .